PMS
Graphs & Metrics
Historical charts and KPIs for your PowerMaster installation.
The Graphs page turns the recorded telemetry, commands and decisions into charts and key figures over a chosen range (today, 24 h, 7 days, or a custom window up to 31 days). It auto-refreshes every 60 seconds while the range includes the present.
KPI cards
- Self-sufficiency — share of consumption covered without grid import.
- Self-consumption — share of PV generation used directly instead of exported.
- Grid import / export and battery throughput (charged / discharged energy).
- Battery round-trip efficiency — only shown when the state of charge ends close to where it started.
- Command success rate — share of applied vs. failed device commands per device.
Charts
- A power-flow chart (PV, house, grid, battery) with state of charge plotted below it.
- Battery set point vs. actual measured power, to see how closely the hardware follows the policy.
- Load power with on/off strips, plus per-load energy and on-time.
- A command table for the selected range, with failed commands highlighted and a "failed only" filter.
Notes
- Only "good" quality samples are used; a data gap longer than 5 minutes is never interpolated or invented.
- Values depend on which devices you have: without a grid meter, consumption and the self-sufficiency/self-consumption ratios cannot be computed and show as unavailable.
- The overview dashboard (PMS Overview) shows a short sparkline per device role plus today's headline numbers and a link into the full Graphs page.
© 2026 JFK-Enterprise Toolbox · JFK Enterprise e.U.